Status: beta. The price ranges in our tools are placeholders while we load verified data; the date of each data set will be shown here.
This page explains how each tool reaches its result, with the formulas we use and the public sources behind them. If you think a number is wrong, write to contact@windowcheckup.com.
Quote checker and quote comparison
The quote checker builds an expected range for each line of your quote, then compares your price with it. The quote comparison runs the same check on two or three quotes side by side.
Windows
Expected range = product range per window × number of windows × size factor × regional factor
- Product range per window: a low and high price for the window type and material you choose.
- Size factor: adjusts for windows that are smaller or larger than a typical unit.
- Regional factor: adjusts for price levels where you live.
Other lines
| Line | How we estimate it |
|---|---|
| Labor | Based on wages for installation trades in your area, from BLS Occupational Employment and Wage Statistics |
| Removal and disposal of old windows | $15 to $40 per window |
| Interior or exterior trim | $40 to $120 per window |
| Permit | Set by your city or county, so it varies widely. Check the fee with your local building department. |
| Lead-safe work practices (homes built before 1978) | $20 to $60 per window |
Why the lead-safe line: under the EPA Renovation, Repair and Painting (RRP) rule, anyone paid to do work that disturbs paint in a home built before 1978 must be certified in lead-safe work practices. Replacing windows in an older home can disturb old paint, so the extra cost is legitimate on those jobs.
Verdict
| Your price | Verdict |
|---|---|
| Below 85% of the low end of the range | Low |
| From 85% of the low end up to the high end | In range |
| Up to 20% above the high end | A bit high |
| More than 20% above the high end | High |
A low price is not automatically good. It can mean a line is missing from the quote or the scope is different.
Measuring assistant
- Measure the width at the top, middle and bottom of the opening. Use the smallest of the three.
- Measure the height at the left, center and right. Use the smallest of the three.
- Insert (pocket) replacement: order size = smallest width minus 1/4 inch, and smallest height minus 1/4 inch.
- Full-frame replacement: order size = rough opening width minus 1/2 inch, and rough opening height minus 1/2 inch.
- Measure both diagonals, corner to corner. If they differ by more than 1/4 inch, the opening is out of square, and the tool warns you to have it checked before ordering.
Always confirm sizes with the manufacturer or your installer before you order.
Triple-pane payback calculator
The calculator estimates how much heating energy you save each year by choosing triple pane over double pane.
Heat saved per year (BTU) = (U-factor double − U-factor triple) × glass area in square feet × heating degree days × 24
U-factor is in BTU per hour, per square foot, per °F. Heating degree days come from NOAA for your location. The 24 turns degree days into degree hours.
The heat saved is then converted to the fuel you use:
| Heating system | Fuel saved per year |
|---|---|
| Natural gas furnace | Heat saved ÷ 100,000 BTU per therm ÷ 0.92 furnace efficiency = therms |
| Heat pump | Heat saved ÷ 3,412 BTU per kWh ÷ 2.5 (heat pump COP) = kWh |
| Electric resistance heat | Heat saved ÷ 3,412 BTU per kWh ÷ 1 = kWh |
Fuel saved × your state’s residential energy price from EIA = dollars saved per year. EIA reports natural gas in dollars per thousand cubic feet, so we convert it to dollars per therm using EIA’s heat content figure.
Payback in years = extra cost of triple pane ÷ dollars saved per year.
Illustration with round numbers, not a real home: a U-factor difference of 0.10, 100 square feet of glass and 6,000 heating degree days gives 0.10 × 100 × 6,000 × 24 = 1,440,000 BTU. With a gas furnace, that is about 15.7 therms a year. With a heat pump, about 169 kWh.
The calculator covers heating only. It does not count cooling savings, comfort or noise.
Standard size finder
The size finder lists common stock window sizes. Window size codes give the width in feet and inches, then the height in feet and inches. For example, 3046 means 3 feet 0 inches wide by 4 feet 6 inches high. Manufacturers differ on whether the code describes the unit or the rough opening, so check their size chart.
Egress windows
Where the code requires an emergency escape and rescue opening, the 2021 International Residential Code (Section R310) sets these minimums:
- Net clear opening area of at least 5.7 square feet. Grade-floor openings may have a net clear opening of 5 square feet.
- Net clear opening height of at least 24 inches.
- Net clear opening width of at least 20 inches.
- Bottom of the clear opening no higher than 44 inches above the floor.
A window that meets only the minimum width and height does not reach 5.7 square feet, so both size and area must be checked. States and cities adopt different code editions and amendments. Confirm with your local building department.
Sources
These are the public sources we use. Each data set will be listed here with its date once loaded.
- U.S. Bureau of Labor Statistics, Occupational Employment and Wage Statistics (labor wages): https://www.bls.gov/oes/
- U.S. Energy Information Administration, average residential natural gas price by state: https://www.eia.gov/dnav/ng/ng_pri_sum_a_EPG0_PRS_DMcf_a.htm
- U.S. Energy Information Administration, average price of electricity by state and sector (Electric Power Monthly, Table 5.6.A): https://www.eia.gov/electricity/monthly/epm_table_grapher.php?t=epmt_5_6_a
- NOAA National Centers for Environmental Information, U.S. Climate Normals, including heating degree days: https://www.ncei.noaa.gov/products/land-based-station/us-climate-normals
- ENERGY STAR, Residential Windows, Doors and Skylights key product criteria by climate zone (Version 7.0, effective October 23, 2023): https://www.energystar.gov/products/residential_windows_doors_and_skylights/key_product_criteria
- U.S. Environmental Protection Agency, Renovation, Repair and Painting (RRP) Program for pre-1978 homes: https://www.epa.gov/lead/renovation-repair-and-painting-program
- International Code Council, 2021 International Residential Code, Chapter 3, Section R310 Emergency Escape and Rescue Openings: https://codes.iccsafe.org/content/IRC2021P2/chapter-3-building-planning